UPS GeTX Online GXK-1-1-3-CO, 3Kv (3000VA) HF LCD battery 12-9 *6
Review: 5 - "A masterpiece of literature" by , written on May 4, 20020
Great
  • electro-track-order-icon
  • Free Delivery
    All Over Iraq
  • electro-thumb
  • 99% Customers
    Feedbacks
  • electro-return-icon
  • 12 Months
    Maintenance Warranty
  • electro-payment
  • Payment
    Cash on delivery
  • electro-brands-icon
  • Best Brands
    New Products Only

UPS GeTX Online GXK-1-1-3-CO, 3Kv (3000VA) HF LCD battery 12-9 *6

Available:In Stock
  • Product SKU: 107298
550.000 IQD 585.000 IQD

Specification

Model: GXK-1-1-3-CO
Capacity: 3000VA / 2700W

Key Features:

  • High power density

  • Online double conversion with full digital control

  • Wide input voltage range (110–300Vac)

  • Input power factor: 0.99 with PFC

  • Selectable output voltage: 208/220/230/240Vac

  • Smart charger design for optimized battery performance

  • Maximum charging current expandable to 12A (long-run unit)

  • Emergency Power Off (EPO) function

  • Versatile LCD human-computer interface

  • ECO mode for energy saving

  • Multiple communication interfaces: RS232 (USB/EPO/Relay/SNMP card optional)


Input:
Nominal Voltage: 208/220/230/240Vac
Input Voltage Range: 110–300Vac (176–280Vac @ 100% load)
Input Frequency Range: 40–70Hz (auto-sensing)
Input Power Factor: ≥0.99

Output:
Output Voltage: 208/220/230/240Vac
Voltage Regulation: ±1%
Power Factor: 0.9
Output Frequency:

  • Line Mode: 46–54Hz or 56–64Hz

  • Battery Mode: 50/60Hz ±0.1Hz
    Crest Factor: 3:1
    Harmonic Distortion:

  • ≤3% Linear Load

  • ≤5% Nonlinear Load
    Transfer Time:

  • AC to Battery: 0ms

  • Inverter to Bypass: 4ms (Typical)
    Output Waveform: Pure Sinewave

Efficiency:
AC Mode: 91%
Battery Mode: 88%

Battery:
Number of Batteries: 6
Capacity: 12V / 9Ah
Recharge Time: 4 hours to 90%
Charging Voltage: 82.2Vdc ±1%
Max Charging Current: 1A

Indicators:
LED Display: Line mode, Battery mode, ECO mode, Bypass mode, Battery low voltage, Overload, UPS fault
LCD Display: Input voltage, frequency, output voltage, output frequency, load %, battery voltage, inner temperature, backup time

Alarm:
Battery Mode: Beeping every 4 seconds
Battery Low: Beeping every second
Overload: Beeping twice every second
Fault: Continuous beeping

Physical:
Dimensions (W × D × H): 191 × 460 × 337 mm
Net Weight: 24.5 kg

Environment:
Operating Temperature: 0–40°C
Storage Temperature: -25–55°C
Humidity: 20–95% RH (non-condensing)
Altitude: <1500m (derating required >1500m)
Noise Level: <50dB @ 1 meter

Standards:
Safety: IEC/EN62040-1, IEC/EN62477-1
EMC: IEC/EN62040-2, IEC61000-4-2/3/4/5/6, IEC61000-4-8

Specification

Model: GXK-1-1-3-CO
Capacity: 3000VA / 2700W

Key Features:

  • High power density

  • Online double conversion with full digital control

  • Wide input voltage range (110–300Vac)

  • Input power factor: 0.99 with PFC

  • Selectable output voltage: 208/220/230/240Vac

  • Smart charger design for optimized battery performance

  • Maximum charging current expandable to 12A (long-run unit)

  • Emergency Power Off (EPO) function

  • Versatile LCD human-computer interface

  • ECO mode for energy saving

  • Multiple communication interfaces: RS232 (USB/EPO/Relay/SNMP card optional)


Input:
Nominal Voltage: 208/220/230/240Vac
Input Voltage Range: 110–300Vac (176–280Vac @ 100% load)
Input Frequency Range: 40–70Hz (auto-sensing)
Input Power Factor: ≥0.99

Output:
Output Voltage: 208/220/230/240Vac
Voltage Regulation: ±1%
Power Factor: 0.9
Output Frequency:

  • Line Mode: 46–54Hz or 56–64Hz

  • Battery Mode: 50/60Hz ±0.1Hz
    Crest Factor: 3:1
    Harmonic Distortion:

  • ≤3% Linear Load

  • ≤5% Nonlinear Load
    Transfer Time:

  • AC to Battery: 0ms

  • Inverter to Bypass: 4ms (Typical)
    Output Waveform: Pure Sinewave

Efficiency:
AC Mode: 91%
Battery Mode: 88%

Battery:
Number of Batteries: 6
Capacity: 12V / 9Ah
Recharge Time: 4 hours to 90%
Charging Voltage: 82.2Vdc ±1%
Max Charging Current: 1A

Indicators:
LED Display: Line mode, Battery mode, ECO mode, Bypass mode, Battery low voltage, Overload, UPS fault
LCD Display: Input voltage, frequency, output voltage, output frequency, load %, battery voltage, inner temperature, backup time

Alarm:
Battery Mode: Beeping every 4 seconds
Battery Low: Beeping every second
Overload: Beeping twice every second
Fault: Continuous beeping

Physical:
Dimensions (W × D × H): 191 × 460 × 337 mm
Net Weight: 24.5 kg

Environment:
Operating Temperature: 0–40°C
Storage Temperature: -25–55°C
Humidity: 20–95% RH (non-condensing)
Altitude: <1500m (derating required >1500m)
Noise Level: <50dB @ 1 meter

Standards:
Safety: IEC/EN62040-1, IEC/EN62477-1
EMC: IEC/EN62040-2, IEC61000-4-2/3/4/5/6, IEC61000-4-8